-40%
Hantek 2 in 1 Handheld oscilloscope 2C42/2C72/2D42/2D72 DMM Multimeter tester
$ 67.05
- Description
- Size Guide
Description
Hantek2000 SeriesAn all-new handheld oscilloscope-Hantek2000 series, it continues the compact and lightweight concept but with a new generation of 3 in 1 multifunction tester: oscilloscope, signal source and multimeter; A small volume of the non-profit grip by a single hand; The suspendingstand was designed to support multi-angle adjustment; Ultra-low-power, Type C charging interface, each 2 hours battery charge allow working one full day or standbytwo months; High-definition color LCD screen display clear and delicate; Minimalist keyboard design simplifyoperation, easy to use.
Model
Hantek2D72
Hantek2D42
Hantek2C72
Hantek2C42
Oscilloscope Mode
Bandwidth
70MHz
40MHz
70MHz
40MHz
Channel
2CH+DMM+AWG
2CH+DMM+AWG
2CH+DMM
2CH+DMM
Horizontal
Sample Rate Range
250MSa/s(Single-channel), 125MSa/s(Dual-channel)
Waveform Interpolation
(sin x)/x
Record Length
Max. 6K for single-channel; 3K samples per dual-channel
SEC/DIV Range
5ns/div~500s/div 1, 2, 5 sequence
Vertical
A/D Converter
8-bit resolution,each channel sampled simultaneously
VOLTS/DIV Range
10mV/div~10V/divat input BNC
Bandwidth Limit, typical
20MHz
Low Frequency Response (-3db)
≤10Hz at BNC
Rise Time at BNC, typical
≤5ns
DC Gain Accuracy
±3% for Normal or Average acquisition mode, 10V/div to 10mV/div
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Acquisition
Acquisition Modes
Normal
Trigger
Type
Edge
Mode
Auto, Normal, single
Level
±4 divisions from center of screen
Trigger Level Accuracy
0.2div × volts/div within ±4 divisions from center of screen
Slope
Rising, Falling, Rising & Falling
Source
CH1/CH2
Input
Coupling
DC, AC or GND
Input Impedance,
25pF±3 pF, 1MΩ±2%
DC coupled
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factors
1X, 10X, 100X, 1000X
Maximum Input Voltage
150V
RMS
Measurement
Cursor
Voltage difference between cursors:
△
V
Time difference between cursors:
△
T
Automatic Measurements
Frequency, Amplitude
Arbitrary Waveform Generator Mode
Waveform Frequency
Sine: 1Hz~25MHz
-
-
Square: 1Hz~10MHz
-
-
Ramp: 1Hz~1MHz
-
-
EXP: 1Hz~5MHz
-
-
Sampling
250MSa/s
-
-
Amplitude
2.5Vpp(50Ω)
-
-
5Vpp(High impedance)
-
-
Frequency Resolution
0.10%
-
-
Channel
1CH waveform output
-
-
Waveform Depth
512Sa
-
-
Vertical Resolution
12 bit
-
-
Output Impedance
50 Ω
-
-
DMM
Maximum Resolution
4000 Counts
DMM Testing Modes
Voltage,Current,Resistance,Capacitance,Diode &On-Off
Maximum Input Voltage
AC:600V, DC: 800V
Maximum Input Current
AC: 10A, DC:10A
Input Impedance
10MΩ
Measurement Term
Range
Accuracy
Resolution
DC Voltage
400.00mV
± (0.8% + 5)
100uV
4.000V
1mV
40.00V
10mV
400.0V
100mV
600.0V
± (1% + 2)
1V
Overload protection: 400mV: 250V, other: 600Vrms.
AC Voltage
4.000V
± (1.2% + 5)
1mV
40.00V
10mV
400.0V
100mV
600.0V
±(1.5% + 5)
1V
Frequency: 40Hz~400Hz;
Frequency of 400V and 600V: 40Hz~100Hz
DC Current
40.00mA
± (1% + 2)
10uA
200.0mA
± (1.5% + 2)
100uA
4.000A
± (1.8% + 2)
1mA
10.00A
± (3% + 2)
10mA
Overload protection:
self restoring fuse: 200mA/250V, 4A and 10A range no fuse.
AC Current
40.00mA
± (1.3% + 2)
10uA
400.0mA
± (1.8% + 2)
100uA
4.000A
± (2% + 3)
1mA
10.00A
± (3% + 5)
10mA
Frequency: 40Hz~400Hz;
self restoring fuse: 200mA/250V, 4A and 10A range no fuse.
Resistance
400.0Ω
±(1% + 3)
0.1Ω
4.000KΩ
±(1.2% + 5)
1Ω
60.00KΩ
10Ω
400.0KΩ
100Ω
4.000MΩ
1KΩ
40.00MΩ
± (1.5%±3)
10KΩ
Overload protection: 220Vrms
Capacitance
40.00nF
±(3% + 5)
10pF
400.0nF
100pF
4.000uF
1nF
40.00uF
10nF
100.0uF
100nF
Overload protection: 220Vrms
Diode
0V~2.0V
On-Off
<50Ω
General Specifications
Display
Display Type
2.8 inch64K color TFT
Display Resolution
320 horizontal by 240 vertical pixels
Display Contrast
Adjustable
Power Supply
Supply Voltage
100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A
Power Consumption
<2.5W
Fuse
T, 3A
Battery
2600mA*2
Environmental
Operating Temperature
0~50 °C (32~122 °F)
Storage Temperature
-40~+71 °C (-40~159.8 °F)
Humidity
≤+104
℉
(≤+40°C): ≤90% relative humidity
106
℉
~122
℉
(+41°C ~50°C): ≤60% relative humidity
Cooling Method
Convection
Altitude
Operating and
3,000m (10,000 feet)
Nonoperating
Mechanical Shock
Random Vibration
0.31g
RMS
from 50Hz to 500Hz, 10 minutes on each axis
Nonoperating
2.46g
RMS
from 5Hz to 500Hz, 10 minutes on each axis
Operating
50g, 11ms, half sine
Mechanical
Dimension
199 x 98x 40mm (L x W x H)
Weight
624g
Standard Accessories
Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1
Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1
Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1
Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1
Shipping:
We will ship all items within 1-3 working days upon receipt of payment,our goal is: ship it as fast as we can.
Standard Shipping: To USA,UK and Australia by ePacket,need 7-12 working days.
Expedited/Standard Int'l Shipping by Fedex,DHL,TNT and EMS courier: To USA,need 3-6 business days,To other countries,need 4-8 business days normally.But sometimes int'l delivery is highly depended on the courier company and local customs/duties.
Import duties and taxes are not included in the item price or shipping charges.These charges are the buyer responsibility.
Warranty&Reture Policy:
We encourage all customers to communicate with us through eBay messages. If you have any questions or comments whatsoever regarding our products or listing, we are waiting to hear from you
A 1 year warranty is offered for this product.If the product malfunctioned under proper usage per instructions
manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs.
30 days evaluation and investigation takes placed after receiving your return item.A brand new replacement unit will be sent to you at our shipping costs if it meets our warranty requirements.
On Feb-05-20 at 15:43:28 PST, seller added the following information: